6-Axis Force Sensor Combined Load Envelope

Assess a 6-axis force sensor combined load envelope with signed tool-offset moments and simultaneous loads. Compare the result with your supplier’s approved combined-load envelope before accepting a sensor.

6-Axis Combined Load Envelope Calculator

Translate a signed TCP wrench, compare L1/RSS screening models, and export a case for supplier review.

Illustrative screening only. Supplier-approved combined-load limits, hardware saturation, accuracy and fatigue life remain unknown.

1. Single-axis reference capacities

All values are required. Presets are invented examples, not HXF specifications. Replace all six references from your configuration document.

5 to 200000 N
5 to 200000 N
10 to 500000 N
0.1 to 20000 Nm
0.1 to 20000 Nm
0.1 to 20000 Nm
2. Sensor-origin → TCP offset

Signed vector from sensor origin to TCP, expressed in sensor axes. This tool translates the wrench; it does not rotate axes.

-5000 to 5000 mm
-5000 to 5000 mm
-5000 to 5000 mm
3. Applied TCP wrench

Use signed pre-tare total loads in the same right-handed sensor axes. Include tool/adapter weight and inertia; these are not added automatically.

-200000 to 200000 N
-200000 to 200000 N
-500000 to 500000 N
-20000 to 20000 Nm
-20000 to 20000 Nm
-20000 to 20000 Nm
4. Screening assumptions

Kd uniformly scales the complete wrench. Use Kd=1 for already captured peaks. The 70% target and 3× escalation default are illustrative choices, not precision, fatigue or overload specifications.

1 to 5 ×
10 to 100 %
1.2 to 5 ×

Neither model is inferred from a manufacturer curve or von Mises stress analysis. L1 ≥ L2 for these ratios; this alone does not establish conservatism against an unknown real envelope.

Loading configuration…

By HexaForce Metrology & Robotics. Created: . Reviewed: . Software calculations and engineering recommendations; final multi-axis acceptance requires configuration-specific drawing approval.

5 Decisions Before Accepting a Combined Load Case

Use the calculator to prepare the case; use configuration-specific evidence to establish acceptance.

01

Separate ratings do not define a combined envelope

Principle: Six reference values alone do not specify how simultaneous loads interact.

Action: Ask for the supplier’s combined-load diagram and its calibration/configuration revision.

Source basis: ATI Force/Torque FAQ (30 March 2020), §§1.1.2, 2.1, 3.1

02

Translate moments before comparing limits

Principle: M_origin = M_TCP + r × F when all vectors use the same sensor axes.

Action: Use a signed origin-to-TCP offset; convert millimeters to meters.

Source basis: Modern Robotics, §3.4: Wrenches

03

Dynamic scaling is an assumption

Principle: One Kd scales the entire entered wrench, including directly entered moments.

Action: Use Kd=1 when using measured peak loads; include missing gravity and inertia separately.

Source basis: ATI: Selecting an F/T System

04

Model reserve is not product acceptance

Principle: L1 and RSS are explicit mathematical screens, not stress analysis or approved hardware curves.

Action: Send the full signed load case and compare the actual supplier envelope before acceptance.

Source basis: ATI Force/Torque FAQ (30 March 2020), §§1.1.2, 2.1, 3.1

05

Calibration and overload are distinct

Principle: An overload limit is not a usable calibrated measuring range.

Action: Check calibration uncertainty, mechanical limits and service-life requirements separately.

Source basis: ATI Force/Torque FAQ (30 March 2020), §§1.1.2, 2.1, 3.1

1. What six separate ratings cannot tell you

Conclusion: combined acceptance requires configuration-specific evidence.

1. Six separate references2. Interaction is unspecified3. Request the combined curve
Conclusion: combined acceptance requires configuration-specific evidence. — conceptual schematic, not measured hardware data.

A capacity table is not automatically a six-dimensional rectangular operating region. Electronics, flexure geometry and calibration can impose different simultaneous-load constraints. Do not combine six maxima without the manufacturer’s explicit combined-load rule.

Equally, the six ratings alone do not prove that simultaneous maxima will instantly yield the sensor. Mechanical damage, electronic saturation and calibration validity are different questions. This page does not infer a stress percentage or failure load from the six entered references.

Known and unknown before supplier review
ItemKnown from this toolStill required
Origin wrenchComputed from your signed inputsApproved origin and axes drawing
Model utilizationL1 or RSS norm of reference ratiosManufacturer interaction rule
Saturation / overloadUnknownInterface status definition and mechanical limits
Accuracy / fatigueUnknownCalibration uncertainty and duty-cycle evidence

Source basis: ATI Force/Torque FAQ (30 March 2020), §§1.1.2, 2.1, 3.1

2. State the reference frame and load case

A load case is a simultaneous signed six-component wrench.

1. Express F, M, r in sensor axes2. Rotate first if axes differ3. Translate moments to origin
A load case is a simultaneous signed six-component wrench. — conceptual schematic, not measured hardware data.

Enter forces in N, moments in Nm and offsets in mm. The offset r points from the sensor measurement origin to the TCP. Express all components in one right-handed sensor coordinate basis. The calculator translates origins only; it has no rotation input.

If TCP axes are rotated relative to the sensor, rotate both F and M into sensor axes first, then apply the translation. Gravity, tool mass, inertia, cable forces and mounting preload are not inserted automatically. Loads acting at other points must be transformed separately and summed at a common origin.

Use simultaneous time-aligned values for a measured load case. Combining independent maxima from different times can be a useful deliberately conservative scenario, but it is not a recorded instantaneous wrench.

Source basis: Modern Robotics, §3.4: Wrenches · On the Calibration of Force/Torque Sensors in Robotics (2019)

3. Reproduce the lever-arm calculation

Example: a 0.2 m extension converts transverse load into bending moment.

1. r: origin → TCP [m]2. Induced moment = r × F3. M_origin = M_TCP + r × F
Example: a 0.2 m extension converts transverse load into bending moment. — conceptual schematic, not measured hardware data.

For r=[0,0,200] mm and F=[100,50,0] N, r × F=[−10,+20,0] Nm. With no direct TCP moments, the origin moments are exactly those induced values. The sign follows the right-hand rule.

At the default deburring example, r=[0,25,180] mm and F=[80,30,120] N produce [−2.40,+14.40,−2.00] Nm. Adding TCP M=[2,4,1.5] Nm gives M_origin=[−0.40,+18.40,−0.50] Nm. Changing an offset can remove an opposing moment; always recalculate rather than assuming a shorter tool is automatically better.

Default example signed moment audit (Nm)
AxisTCP momentr × FOrigin moment
Mx2-2.4-0.4
My414.418.4
Mz1.5-2-0.5

Source basis: Modern Robotics, §3.4: Wrenches

4. Compare the two screening models

Both use positive single-axis reference capacities C_i.

1. u_i = |load_i| / reference_i2. RSS = √Σu_i²; L1 = Σu_i3. L1 ≥ RSS; actual limit unknown
Both use positive single-axis reference capacities C_i. — conceptual schematic, not measured hardware data.

Define u_i=|w_i|/C_i for the six sensor-origin wrench components. RSS/L2 uses U=√Σu_i². L1 uses U=Σu_i. The reference boundary is U=1; neither formula is fitted to a specific transducer.

For six equal reference ratios of 1, RSS gives √6=2.449 and L1 gives 6.000. Compare both screens for the same signed load case to see how the model choice changes the result without changing the physical inputs.

L1 is always greater than or equal to RSS for the same nonnegative ratios. This is a mathematical comparison between these screens, not proof that L1 bounds an unknown physical envelope. A real interaction model may include cross terms, sign dependence, calibration-specific gage limits and non-elliptical boundaries.

Model comparison — analytical definitions, not manufacturer specifications
ModelEquationReproducible illustrationLimit
RSS / diagonal ellipsoidU=√Σu_i²Six unit ratios → √6=2.449No interaction cross terms
Absolute sum / L1U=Σu_iSix unit ratios → 6.000Not a proven bound on unknown hardware
Supplier curve / matrixConfiguration-specificNot entered or evaluated hereUse approved documentation for acceptance

Basis: analytical definitions and illustrative calculations stated in this section; not a manufacturer specification.

5. Separate assumed amplification from measured peaks

Kd is an explicit uniform scenario multiplier, not a duty-cycle model.

1. Enter one simultaneous wrench2. Uniform scale U_peak = Kd × U3. Use Kd = 1 for measured peaks
Kd is an explicit uniform scenario multiplier, not a duty-cycle model. — conceptual schematic, not measured hardware data.

The calculator uses U_scaled=Kd × U_static. This is valid for the chosen mathematical norm when all six wrench components scale by the same positive factor. It cannot represent independently varying components, resonance, impact duration or a load time history.

The presets use illustrative Kd values. They are not recommended factors for all deburring, heel-strike or wind-tunnel systems. For measured peak cases use Kd=1; for mixed static and dynamic components, construct the peak wrench externally and enter it directly.

Fatigue needs a duty cycle, load reversals and configuration-specific evidence. No endurance limit or service life follows from 70% utilization, a positive model margin or this calculator’s escalation factor.

Source basis: ATI Force/Torque FAQ (30 March 2020), §§1.1.2, 2.1, 3.1 · ATI: Selecting an F/T System

6. Interpret reserve and margin without overstating confidence

RF=1/U_scaled and MS=RF−1 refer to the selected U=1 model boundary.

1. U refers to selected model2. Model reserve RF = 1 / U3. Model margin MS = RF − 1
RF=1/U_scaled and MS=RF−1 refer to the selected U=1 model boundary. — conceptual schematic, not measured hardware data.

For U_scaled=0.5, RF=2 and MS=1. This is the load multiplier to the analytical boundary along the same proportional loading direction. Your chosen screening target is a separate planning criterion; RF is not calculated against that target.

For zero load, RF and MS are unbounded within the model. The tool shows “Unbounded (zero load)” and no governing axis, rather than inventing a finite reserve. No assembly has infinite mechanical capacity.

The default 70% target and 3× escalation threshold are illustrative user settings. The escalation threshold never grants permission to operate between U=1 and the threshold.

Result → action mapping (analytical screen only)
StateMeaningMinimum next action
Below targetScaled U ≤ user targetAsk supplier to confirm real envelope and calibration
Above targetTarget < scaled U ≤ 1Compare design alternatives and uncertainty
Scaled model exceededStatic U ≤ 1, scaled U > 1Build measured peak cases; review Kd
Static model exceededStatic U > 1Revisit loads / offsets / capacities
Escalation exceededScaled U > user escalation factorReduce proposed case and obtain engineering review

Basis: analytical definitions and illustrative calculations stated in this section; not a manufacturer specification.

7. Keep measurement, saturation and mechanical limits separate

A generic calculator cannot read a hardware status register.

1. Calibration measurement range2. Separate mechanical limits3. Stop presence / rating unknown
A generic calculator cannot read a hardware status register. — conceptual schematic, not measured hardware data.

ATI’s FAQ distinguishes calibrated range, saturation errors and single-axis overload. That source describes ATI equipment; it does not establish a universal equation or bit assignment for all sensors or HXF configurations. Read the exact device/interface manual and actual status words.

VDI/VDE/DKD 2638:2025-09 is listed as a terms-and-definitions guideline for force transducers. Its public listing does not establish universal 130% or 150% operating bands or prove that a device has internal stops. The paid standard text was not used to certify this tool.

A bias/tare operation changes the reported zero; it does not unload a flexure or restore physical headroom. Mechanical stops, if provided, also need their own engagement, energy and installation evidence.

Separate acceptance evidence
QuestionEvidence to requestTool status
Can it measure this combination?Calibration-specific combined range / gage constraintsUnknown
Will it survive a transient?Mechanical combined overload limits and durationUnknown
Does protection engage?Stop design and assembly requirementsUnknown
Will it meet uncertainty?Calibration report at relevant loads and environmentUnknown

Source basis: ATI Force/Torque FAQ (30 March 2020), §§1.1.2, 2.1, 3.1 · VDI/VDE/DKD 2638:2025-09 — Characteristics of force transducers: Terms and definitions

8. Compare risks, costs and alternatives

Choose a mitigation that addresses the actual governing load.

A larger capacity candidate may reduce model utilization but also change mass, stiffness, dimensions, resolution and price. Obtain a configuration-specific quote and uncertainty evidence; this page provides no prices or available-SKU claim.

Mounting, thermal gradients and cable reaction loads can change the installed behavior. Include tool-side adapter stack-up in the origin-to-TCP distance. Check fasteners, thread engagement and adapter flange requirements independently of the sensor reference capacities. Follow the selected supplier’s mounting instructions and characterize the installed assembly rather than reserving an invented universal percentage.

Software monitoring can support process control but does not guarantee that an impact will be arrested before overload. Evaluate controller and braking latency, credible impacts and independent protection appropriate to the application. This page is not a safety function or robot risk assessment.

Risk and tradeoff register
RiskConsequenceMitigation / alternative
Misuse: norm treated as approvalUnverified combined loadingObtain supplier envelope; retain signed load cases
Cost: oversizing every referenceMass / resolution / integration penaltyCompare shorter tool and capacity candidates
Scenario mismatch: impact with static KdUncaptured peak or durationMeasure complete peak wrench and duty cycle
Missing configuration evidenceAcceptance cannot be establishedPause physical acceptance; request drawing / calibration review

Source basis: ATI: Selecting an F/T System · ATI Force/Torque FAQ (30 March 2020), §§1.1.2, 2.1, 3.1

9. Use a repeatable supplier-review protocol

A complete handoff should let another engineer reproduce the screen.

1. Capture signed load cases2. Compare supplier envelope3. Verify calibration + mechanics
A complete handoff should let another engineer reproduce the screen. — conceptual schematic, not measured hardware data.

Record the configuration identifier, calibration identifier, capacity source/revision, origin drawing, axis convention, units and load-case date. Preserve the full signed TCP wrench and offset alongside the transformed origin wrench.

Copy the screening memo or share the configuration URL. The link includes every numeric field, including values that match global defaults, so a selected example cannot silently replace an edited value on reload.

Compare each proposed origin wrench against the exact approved simultaneous-load limits, then independently review calibrated measuring range, overload constraints, load history and uncertainty. If the supplier rule is unavailable or does not match either model, mark acceptance unresolved. Do not force-fit the real curve to RSS.

  • Confirm load origin and frame; independently spot-check the cross product.
  • Reproduce the case with both screens to understand model sensitivity.
  • Resolve missing supplier evidence before physical test acceptance.

Source basis: ATI Force/Torque FAQ (30 March 2020), §§1.1.2, 2.1, 3.1 · ATI: Selecting an F/T System

10. Reproduce four illustrative application cases

Each case below uses the same calculation function and exact preset inputs.

These are invented engineering scenarios, not production deployments, verified HXF models or measured performance. Capacities, forces, direct moments, offsets, Kd, screening target and escalation factor are all included in each case and its “Load this example” link.

The numerical results are generated from the calculator rather than transcribed. Applying the same link produces the same transformed wrench and utilization. The result establishes an analytical screening observation only.

Basis: analytical definitions and illustrative calculations stated in this section; not a manufacturer specification.

Original browser capture: reproduce the default case

Captured on 6 November 2026 in Chrome at a 1440 × 1000 viewport. The deburring example uses F=[80,30,120] N, TCP M=[2,4,1.5] Nm, r=[0,25,180] mm, capacities F=[500,500,900] N and M=[20,20,20] Nm, Kd=1.4, target=70%, escalation=3× and the RSS model. The signed origin moments are [−0.40,18.40,−0.50] Nm; scaled utilization is 132.40%. Reproduce these values with the default example above.

Combined load envelope calculator default RSS result showing signed origin wrench, 132.40% scaled utilization and unresolved supplier acceptance
Actual software execution with illustrative inputs. This capture is evidence of calculator behavior; it provides no physical sensor test, customer endorsement or approved combined-load rating.

Next step: prepare a configuration-specific load-case review.

Four Reproducible Illustrative Load Cases

Illustrative scenarioSupplier acceptance unresolved

Cobot Wrist Deburring Spindle (illustrative)

Evidence status: No verified product specification

Illustrative references: Fx=500, Fy=500, Fz=900 N; Mx=20, My=20, Mz=20 Nm

Inputs: TCP F=[80, 30, 120] N; M=[2, 4, 1.5] Nm; Kd=1.4; target=70%; escalation=3×

Tool Overhang Lever Arm: [0, 25, 180] mm (sensor origin → TCP)

Transformed Origin Wrench: Fx=80.00 N; Fy=30.00 N; Fz=120.00 N; Mx=-0.40 Nm; My=18.40 Nm; Mz=-0.50 Nm

Envelope Evaluation:

RSS: static U=94.57%; scaled U=132.40%; model RF=0.76; model MS=-0.24.

Engineering Mitigation: The uniform dynamic scaling takes this case beyond the model boundary. Obtain measured peak load cases including gravity and inertia, then recalculate without double-counting peaks.

Load this example ↗
Illustrative scenarioSupplier acceptance unresolved

Humanoid Biped Ankle Heel-Strike (illustrative)

Evidence status: No verified product specification

Illustrative references: Fx=2500, Fy=2500, Fz=5000 N; Mx=150, My=150, Mz=150 Nm

Inputs: TCP F=[420, 190, 2600] N; M=[18, 48, 9] Nm; Kd=1.8; target=75%; escalation=3.5×

Tool Overhang Lever Arm: [45, 15, 65] mm (sensor origin → TCP)

Transformed Origin Wrench: Fx=420.00 N; Fy=190.00 N; Fz=2600.00 N; Mx=44.65 Nm; My=-41.70 Nm; Mz=11.25 Nm

Envelope Evaluation:

RSS: static U=68.99%; scaled U=124.18%; model RF=0.81; model MS=-0.19.

Engineering Mitigation: The uniform dynamic scaling takes this case beyond the model boundary. Obtain measured peak load cases including gravity and inertia, then recalculate without double-counting peaks.

Load this example ↗
Illustrative scenarioSupplier acceptance unresolved

Precision Micro-Peg Insertion (illustrative)

Evidence status: No verified product specification

Illustrative references: Fx=250, Fy=250, Fz=1000 N; Mx=6, My=6, Mz=6 Nm

Inputs: TCP F=[18, 12, 65] N; M=[0.15, 0.22, 0.08] Nm; Kd=1.2; target=65%; escalation=3×

Tool Overhang Lever Arm: [0, 0, 60] mm (sensor origin → TCP)

Transformed Origin Wrench: Fx=18.00 N; Fy=12.00 N; Fz=65.00 N; Mx=-0.57 Nm; My=1.30 Nm; Mz=0.08 Nm

Envelope Evaluation:

RSS: static U=26.05%; scaled U=31.26%; model RF=3.20; model MS=2.20.

Engineering Mitigation: The case is below your chosen screening target. Export this load case and ask the supplier to confirm the actual envelope and calibration uncertainty; no accuracy or safety acceptance follows from this result.

Load this example ↗
Illustrative scenarioSupplier acceptance unresolved

Sub-Scale Wind Tunnel Model (illustrative)

Evidence status: No verified product specification

Illustrative references: Fx=15000, Fy=15000, Fz=30000 N; Mx=1500, My=1500, Mz=1500 Nm

Inputs: TCP F=[2200, 450, 9800] N; M=[180, 750, 110] Nm; Kd=1.15; target=80%; escalation=3×

Tool Overhang Lever Arm: [120, 0, 90] mm (sensor origin → TCP)

Transformed Origin Wrench: Fx=2200.00 N; Fy=450.00 N; Fz=9800.00 N; Mx=139.50 Nm; My=-228.00 Nm; Mz=164.00 Nm

Envelope Evaluation:

RSS: static U=41.57%; scaled U=47.81%; model RF=2.09; model MS=1.09.

Engineering Mitigation: The case is below your chosen screening target. Export this load case and ask the supplier to confirm the actual envelope and calibration uncertainty; no accuracy or safety acceptance follows from this result.

Load this example ↗

12 FAQs: Combined Load Envelope Decisions

Answers distinguish mathematical screening from supplier-confirmed performance. Figures in worked examples are illustrative.

Physics & Mechanics

Can six single-axis maxima be applied together?

Only if the exact supplier documentation explicitly permits that combination. Six separate ratings are insufficient to infer a combined-load envelope.

Source basis: ATI Force/Torque FAQ (30 March 2020), §§1.1.2, 2.1, 3.1

Does U greater than 100% prove mechanical damage?

No. It exceeds the chosen model boundary. Saturation, calibrated range, mechanical overload and fatigue are separate device-specific constraints.

Source basis: ATI Force/Torque FAQ (30 March 2020), §§1.1.2, 2.1, 3.1

Does taring restore physical capacity?

No. Tare changes the reported zero while physical loads remain. Keep gravity and payload loads in the mechanical load assessment.

Source basis: ATI Force/Torque FAQ (30 March 2020), §§1.1.2, 2.1, 3.1

Mathematical Formulations

Is this RSS model a von Mises stress calculation?

No. It is a diagonal norm of normalized wrench components. No flexure geometry, material strength or stress-transfer matrix is supplied.

Is L1 always safe because it exceeds RSS?

No. L1 ≥ RSS for identical ratios, but neither is proven to bound the unknown manufacturer envelope.

What does an unbounded reserve at zero load mean?

The model has no applied wrench and 1/U diverges. This is not infinite hardware strength or an acceptance result.

Tool Offsets & Dynamics

Which direction does the offset vector point?

From sensor measurement origin to TCP, expressed in the sensor axes. Convert mm to m before calculating r × F.

Source basis: Modern Robotics, §3.4: Wrenches

Can I enter forces in rotated TCP axes?

Rotate the force and direct moment into sensor axes first. This tool only translates the wrench and does not perform coordinate rotation.

Source basis: Modern Robotics, §3.4: Wrenches

Should I amplify already measured peak loads?

Use Kd=1 for a complete measured peak case unless you explicitly justify an additional scenario allowance. A scalar factor does not model an impact time history.

Source basis: ATI: Selecting an F/T System

Sizing & Selection

Does the calculator predict hardware saturation or a status bit?

No. Read actual diagnostics using the exact device/interface manual. The calculator has no hardware connection or gage-level calibration model.

Source basis: ATI Force/Torque FAQ (30 March 2020), §§1.1.2, 2.1, 3.1

Are these HXF capacity specifications?

No. All four example capacity sets are illustrative. Obtain an approved configuration drawing, calibration range and combined-load limits for a real selection.

What if no combined-load documentation is available?

Export the signed load cases and request supplier confirmation. Until then, actual acceptance remains unresolved; neither a positive model margin nor a higher escalation factor resolves it.

Source basis: ATI Force/Torque FAQ (30 March 2020), §§1.1.2, 2.1, 3.1

Prepare a Configuration-Specific Load Envelope Review

Send your robot flange drawings, Tool Center Point (TCP) lever arm coordinates, and expected process forces to our engineering team. We can review the load-case assumptions and confirm what configuration-specific drawings, combined-load limits and calibration evidence are available. Analysis scope and acceptance criteria require agreement before testing.

Need related calibration procedures? Check our combined load calibration guide, design & calibration fundamentals, or explore all engineering resources.

Request Envelope Feasibility Review ↗

Primary References, Scope & Review Date

Sources checked on 2026-11-06. Manufacturer guidance is scoped to its own equipment; analytical examples are not verified HXF specifications. Paid standard text was not reviewed.

Standard / LiteratureGoverning Body / PublisherRelevance to Combined Load Envelopes
ATI Force/Torque FAQ (30 March 2020), §§1.1.2, 2.1, 3.1 ↗ATI Industrial AutomationManufacturer guidance on calibrated range, saturation, separate overload limits and load monitoring. Applies to ATI systems; not evidence of HXF ratings.
ATI: Selecting an F/T System ↗ATI Industrial AutomationMoment-driven selection and range/resolution tradeoffs. Does not validate this calculator’s interaction model.
Modern Robotics, §3.4: Wrenches ↗Lynch & Park / Northwestern UniversityWrench representation, moment from r × F and frame transformations.
On the Calibration of Force/Torque Sensors in Robotics (2019) ↗Fredrik Bagge Carlson / arXiv:1904.06158Sensor-frame alignment, payload mass and gravity/center-of-mass identification. Not a mechanical envelope certification.
VDI/VDE/DKD 2638:2025-09 — Characteristics of force transducers: Terms and definitions ↗VDI / DIN MediaPublic scope and edition record checked. Full paid text not reviewed; no universal 130%/150% regimes or mechanical stop claims are inferred.