Home/6-axis sensors/Combined load calibration
Verification worksheet + engineering guide

6-Axis Force Sensor Combined Load Calibration

Check one independent load vector, inspect signed residuals, and plan the evidence needed for a combined-load calibration review.

Combined-load residual worksheet

Compare one held-out reference wrench with six indicated outputs. Plan a test budget below.

Loading worksheet controls…

Worksheet inputs

1. Reference and indicated wrench

Required: reference values in the sensor frame. Indicated outputs may be left blank until measured. Both must use the same origin, sign, tare and units.

-50000 to 50000.
-100000 to 100000; optional until evidence is available.
-50000 to 50000.
-100000 to 100000; optional until evidence is available.
-100000 to 100000.
-200000 to 200000; optional until evidence is available.
-5000 to 5000.
-10000 to 10000; optional until evidence is available.
-5000 to 5000.
-10000 to 10000; optional until evidence is available.
-5000 to 5000.
-10000 to 10000; optional until evidence is available.
2. Capacities and decision inputs

Defaults are hypothetical capacities; replace them with the applicable ratings. FS means positive channel capacity, not the total ± span. The editable 0.25% default is a project target, not an ISO accuracy class.

5 to 50000.
5 to 50000.
10 to 100000.
0.5 to 5000.
0.5 to 5000.
0.5 to 5000.
0.001 to 10.
0.000001 to 10; optional until evidence is available.

U must cover the full error measurement, including reference, mounting, repeatability and readout, at the stated coverage factor. Use a conservative common % FS bound for all six axes. An unknown U prevents acceptance.

3. Test budget and model under review

Changing this label does not change residuals. Supply new indicated readings to compare another fitted model.

3 to 11; whole numbers.
12 to 128; whole numbers.
10 to 50.
0.1 to 120.

Awaiting six indicated outputs

Point-level worksheet only. This does not certify the sensor, validate a fitted matrix, or approve combined-load safety.

Max absolute channel errorAwaiting readings
Normalized six-axis RMSAwaiting readings

Signed error = indicated − reference; eᵢ = 100 × error / capacity. RMS = √(Σeᵢ²/6), a normalized summary rather than a physical force/moment norm.

Decision rule: max |eᵢ| + U ≤ T. Acceptance interval unknown until U is supplied. No probability of false acceptance is calculated.

One verification point: signed errors by axis (% FS)
AxisReferenceIndicatedErrorError % FS
Fx (N)150UnknownUnknownUnknown
Fy (N)80UnknownUnknownUnknown
Fz (N)600UnknownUnknownUnknown
Mx (N·m)15UnknownUnknownUnknown
My (N·m)22UnknownUnknownUnknown
Mz (N·m)8UnknownUnknownUnknown

Combined-load envelope: unknown. No individual reference component exceeds its entered capacity. This alone does not establish a safe simultaneous load. Obtain the manufacturer interaction diagram.

Matrix condition number: unavailable. No matrix or raw bridge dataset is supplied. Compute SVD externally after documenting normalization.

Planned test budget: 135 points

5 levels × 6 axes × 2 sweeps = 60 single-axis fitting points; plus 36 compound vectors.

Holdouts: ceil(25% of fitting count), minimum 6 = 24. Tare checks: ceil((fit + holdout)/8), minimum 4 = 15.

At 3 min/point: 6.75 hours, excluding setup, stabilization, repeats and rework. Counts are planning assumptions; they do not generate a full-rank DoE or prescribe load signs.

Next actions

  • Confirm the manufacturer combined-load interaction diagram before applying this vector; individual spans do not prove safety.
  • Enter six indicated outputs from a held-out verification point, in the same frame and units as the references.
  • Obtain a full per-axis uncertainty budget. A common U in % FS is usable only if it conservatively covers all six axes at this point.
  • Fit the real design matrix externally using QR/SVD; point counts do not establish full rank or adequate coverage.
Share worksheetRequest engineering review ↗

By HexaForce Metrology & Robotics. Created: . Reviewed: . Software worksheet and engineering recommendations; physical calibration evidence must be supplied separately.

Ten Decisions for Combined-Load Calibration

Start with the reference frame, independent readings and agreed limits. These recommendations distinguish measured evidence from planning assumptions.

Combined loading

Verify interactions under simultaneous loads

Decision: Use held-out compound vectors representative of operation.

Single-axis tests can identify linear cross-sensitivity, but may leave nonlinear interactions untested. No universal error percentage follows from the sensor type.

Model choice

Compare measured errors on the same holdouts

Decision: Keep the simpler model if added terms do not improve independent results.

A quadratic expansion adds fitting parameters and validation cost. Higher order alone does not guarantee lower operational errors.

Engineering recommendation; see source scope

Source basis: NIST/SEMATECH: Selecting an experimental design

Numerical stability

Compute conditioning from the actual matrix

Decision: Document scaling and use singular values; capacity ratios cannot substitute for a matrix.

For a full-rank scaled matrix, kappa₂ = sigma_max / sigma_min. Compare like normalization and assess propagated uncertainty rather than enforcing an invented universal threshold.

Engineering recommendation; see source scope

Source basis: BIPM/JCGM: GUM and measurement uncertainty publications

Independent evidence

Separate fitting, selection and final verification

Decision: Freeze final test points before fitting or model selection.

A user-selected holdout budget is not a standard percentage. If holdouts are repeatedly used to tune the model, create another final confirmation set.

Engineering recommendation; see source scope

Source basis: NIST/SEMATECH: Selecting an experimental design

Decision rule

Agree the tolerance and guard rule first

Decision: This worksheet checks maximum absolute normalized error + U ≤ T.

U must be a valid conservative expanded uncertainty bound for the error at this point. Point acceptance does not certify the whole loading domain.

Engineering recommendation; see source scope

Source basis: ILAC G8:09/2019 — Decision Rules and Statements of Conformity

Experimental coverage

Count parameters and check design rank

Decision: Use a constrained design with enough independent compound vectors.

Six linear and 21 unique quadratic terms give 27 features after tare removal; an intercept makes 28. Pure-axis rows cannot identify pair interactions.

Engineering recommendation; see source scope

Source basis: NIST/SEMATECH: Central Composite Designs

Load planning

Get the manufacturer interaction diagram

Decision: Individual capacities do not define a combined-load boundary.

The worksheet blocks an individual overrange reference. Below every span, combined structural safety remains unknown until the actual interaction rule is checked.

Environment

Record stability and zero returns

Decision: Set dwell, temperature and repeat series using measured behavior and the agreed procedure.

No universal 24-hour soaking time or cleanroom requirement is asserted. Log drift so changing zero does not get mistaken for cross-talk.

Engineering recommendation; see source scope

Source basis: BIPM/JCGM: GUM and measurement uncertainty publications

Data integrity

Preserve coefficient metadata and test vectors

Decision: Version matrix, units, row order, frame origin and firmware together.

Machine-readable delivery reduces transcription steps, but schema validation and independent known-vector checks are still necessary.

Engineering recommendation; see source scope

Source basis: PTB Digital Calibration Certificate project

Scope

Separate static calibration from dynamic validation

Decision: Characterize the assembled sensor, tool, filters and controller when frequency response matters.

Static residuals do not establish dynamic magnitude or phase accuracy. No universal fraction of resonance establishes usable bandwidth.

1. What combined loading adds to single-axis tests

Combined-load verification tests whether the fitted response transfers to simultaneous forces and moments.

In a linear model, single-axis reference loads can identify all columns of the sensitivity matrix, including off-axis responses. It is therefore incorrect to say that every single-axis calibration ignores cross-talk. The missing evidence is whether superposition remains adequate over the actual compound operating domain.

Nonlinear elastic response, fixture deflection, load-origin offsets, thermal drift and readout effects can leave residuals under simultaneous loading. Their magnitudes depend on the assembly and dataset. This page makes no claim that combined residuals are always 1.5–3.5% FS or that any model achieves a universal reduction.

Test the superposition assumption: three sequential checks123
  1. Record all outputs during single-axis reference sweeps.
  2. Apply independent compound vectors within approved limits.
  3. Compare signed residuals and investigate interactions.
Test the superposition assumption. Combined-load errors require measurements; no universal error percentage applies.
1. What combined loading adds to single-axis tests — review checklist
Check or optionMethod / decisionEvidence or limitation
Single-axis reference sweepRecord all six outputs, not just the loaded channelIdentifies linear sensitivities and cross-responses
Compound holdout vectorCompare indicated and reference wrenchChecks transfer to simultaneous loading
Repeated vector at reversed signsSeparate drift, hysteresis and sign-dependent effectsRequires documented zero and loading history

Source basis: Acta IMEKO (2017): Multi-component measuring device — uncertainty budget and signal cross-talk for combined loads

2. Linear and quadratic models: useful complexity

Select the model on independent performance, not on its coefficient count.

Let s be six tare-corrected bridge signals and w the reference wrench. A linear inverse calibration is w_hat = K s with K of size 6×6. Fit an overdetermined dataset using QR or SVD; explicitly forming normal-equation inverses can worsen numerical sensitivity. This worksheet consumes already decoupled readings and does not fit K.

A full quadratic feature vector has six linear terms, six squares and 15 unique pair products: 27 terms per output, or 162 coefficients. A fitted constant adds one feature per output. Training residuals can fall even when independent prediction deteriorates. Use the same frozen holdouts, frame and uncertainty treatment for each candidate.

Choose model complexity using holdouts: three sequential checks123
  1. Fit a linear 6×6 model to the reference data.
  2. Evaluate a quadratic expansion only with adequate feature excitation.
  3. Compare candidates on the same independent vectors.
Choose model complexity using holdouts. More parameters do not guarantee better independent results.
2. Linear and quadratic models: useful complexity — review checklist
Check or optionMethod / decisionEvidence or limitation
Linear 6×636 coefficients after zero removalBaseline; pure-axis and compound validation needed
Quadratic 6×27162 coefficients after zero removalNeeds independent excitation of 15 pair terms
Quadratic with offset28 features per outputDo not silently discard the intercept on import

Source basis: NIST/SEMATECH: Selecting an experimental design · NIST/SEMATECH: Central Composite Designs

3. Conditioning: what can and cannot be inferred

A condition number requires an actual matrix and a stated normalization.

For a full-rank scaled matrix A, kappa₂(A) = sigma_max/sigma_min. If the smallest singular value vanishes, the inverse problem is singular. Units and scaling affect the number: mixing N and N·m without stating the transformation makes comparisons ambiguous. State whether A is the sensor sensitivity matrix or the experimental feature matrix.

The number bounds relative sensitivity in a specified norm; it is not an absolute conversion from microvolts to newtons. Evaluate the noise covariance and calibration uncertainty through the actual inverse model. The worksheet reports conditioning as unavailable because capacities and rig names contain none of the required matrix entries.

Conditioning needs an actual scaled matrix: three sequential checks123
  1. Document matrix identity, units and normalization.
  2. Compute singular values using SVD.
  3. Assess sensitivity and propagated uncertainty.
Conditioning needs an actual scaled matrix. kappa₂ = sigma_max / sigma_min; no matrix means no computed condition number.
3. Conditioning: what can and cannot be inferred — review checklist
Check or optionMethod / decisionEvidence or limitation
No matrixReport unknownDo not invent kappa from channel capacity ratios
Scaled matrix availableRetain singular values and scalingCompare only equivalent units and conventions
Small singular directionReview excitation and noise propagationNo universal 1.35 or 2.50 acceptance threshold

Source basis: BIPM/JCGM: GUM and measurement uncertainty publications · NIST/SEMATECH: Selecting an experimental design

4. Rig architecture and the evidence to request

A rig name describes a mechanism, not a traceability or uncertainty rating.

A Stewart-type loading machine or coordinated actuator bench can automate compound vectors, but actuator reference calibration, joint behavior, frame geometry and cross-axis force control must be characterized. A deadweight-and-pulley or cantilever fixture can be useful for traceable loads when mass, local gravity, lever geometry, friction and alignment are included.

Compare laboratories on the actual ranges, signed vector combinations, reference traceability and point-specific uncertainty they can deliver. Confirm fixture tooling, mounting torque, temperature and data export before booking. A low headline uncertainty for one force direction does not imply the same uncertainty for all six simultaneous components.

Qualify the complete reference chain: three sequential checks123
  1. Define signed load combinations and fixture geometry.
  2. Request range-specific traceability and uncertainty.
  3. Agree dwell, repeats, outputs and service scope.
Qualify the complete reference chain. Architecture names alone do not specify uncertainty or throughput.
4. Rig architecture and the evidence to request — review checklist
Check or optionMethod / decisionEvidence or limitation
Actuated platform / benchRequest reference calibration and coupled-control methodThroughput and U require measured facility evidence
Deadweight / pulleyInclude mass, local gravity, friction and alignmentGravity direction alone does not generate six independent DOF
Cantilever gravity fixtureUse M = r × F at the declared originMoment components are coupled to the applied forces

Source basis: Acta IMEKO (2017): Multi-component measuring device — uncertainty budget and signal cross-talk for combined loads · ISO/IEC 17025:2017 — Competence of testing and calibration laboratories

5. A repeatable combined-loading test plan

The budget is a starting allowance; a valid design additionally needs independent features and approved load combinations.

First define the manufacturer-approved load region and application vectors. Normalize candidate coordinates, specify the model terms, then select feasible fitting vectors that give full column rank and acceptable predictive uncertainty. A full five-level grid has 5^6 = 15,625 combinations; it is rarely an efficient first plan. NIST describes central composite designs, but clipping an unsafe design can destroy its rank and balance.

The worksheet budgets 6 axes × L levels × 2 sweeps plus C compound fitting vectors. Holdouts = max(6, ceil((single + C) × ratio/100)); zero checks = max(4, ceil((fit + holdout)/8)). With L=5, C=36 and ratio=25%, this is 60+36+24+15=135 runs. At 3 min/run, budget 6.75 hours before setup, stabilization, repeated sign series and rework. These allowances are not a prescribed standard or a generated D-optimal design.

Design before counting runs: three sequential checks123
  1. Define feasible candidate vectors and model features.
  2. Check rank and predictive uncertainty of the fitting design.
  3. Reserve separate final verification vectors and repeated checks.
Design before counting runs. Run counts do not constitute a generated CCD or D-optimal design.
5. A repeatable combined-loading test plan — review checklist
Check or optionMethod / decisionEvidence or limitation
Linear modelCheck rank of the actual scaled signal matrixRun count alone cannot establish identifiability
Quadratic modelCheck all 27 or 28 feature columnsPure-axis rows leave pair-product columns at zero
Budget and scheduleAdd setup, repeats, sign series and reworkNo guaranteed throughput or laboratory quotation

Source basis: NIST/SEMATECH: Selecting an experimental design · NIST/SEMATECH: Central Composite Designs

6. Independent verification vectors and record format

Choose final verification vectors before fitting and preserve their raw records.

Use application-relevant signs, magnitudes and force/moment ratios, including points between fitting levels. The candidate vectors below are hypothetical, using capacities [500,500,1500] N and [50,50,50] N·m at one sensor origin. They are not loading instructions: obtain manufacturer and rig approval before using them. Do not mix samples taken at different dwell times into one reference vector.

For each vector, retain reference wrench, six raw bridge signals, decoupled readings for each candidate model, tare, timestamp, mounting conditions and uncertainty. Never refit on the final holdout results and still describe them as independent. Reserve additional confirmation points if model selection has used the first validation set.

Keep final verification independent: three sequential checks123
  1. Freeze fitting and model-selection datasets.
  2. Collect final holdouts with raw signals and references.
  3. Retain signed errors and uncertainty for each point.
Keep final verification independent. Reusing final holdouts to tune a fit removes their independence.
6. Independent verification vectors and record format — review checklist
Check or optionMethod / decisionEvidence or limitation
V1: mixed shear and normal[150,80,600] N; [15,22,8] N·mHypothetical default; verify combined envelope
V2: reverse tangential signs[-120,60,450] N; [10,-16,-5] N·mChecks a different sign combination; no result invented
V3: normal and torsion[0,0,750] N; [0,0,12] N·mApplication-specific candidate; readings and U still needed

Source basis: NIST/SEMATECH: Selecting an experimental design · Acta IMEKO (2017): Multi-component measuring device — uncertainty budget and signal cross-talk for combined loads

7. Residual visualization and a reproducible example

Compare signed channel errors in physical units and after a declared normalization.

The worksheet uses error = indicated − reference. With capacity 500 N, reference Fx=150 N and indicated Fx=150.5 N, the signed error is +0.5 N, or +0.1% FS. FS is the positive rated capacity, not the 1000 N peak-to-peak span of a ±500 N channel. Keep physical errors for force/moment budgets, including near zero where percent-of-reading becomes unstable.

The hypothetical example has normalized errors [0.1,0.05,0.1,0.1,0.1,0.05]% FS. Its maximum absolute error is 0.1% FS and normalized RMS is sqrt(0.045/6)=0.086603% FS. This RMS is neither RSS nor a physical six-dimensional force radius; N and N·m cannot be added without a defined metric. The table preserves the six signed components instead of hiding a bad axis behind an average.

Normalize without mixing physical units: three sequential checks123
  1. Subtract reference from each indicated output.
  2. Divide by the positive capacity and multiply by 100.
  3. Inspect six signed errors before maximum and RMS summaries.
Normalize without mixing physical units. Normalized RMS is sqrt(sum(e_i²)/6), not RSS or a physical wrench radius.
7. Residual visualization and a reproducible example — review checklist
Check or optionMethod / decisionEvidence or limitation
Signed channel errore_i = 100 × (indicated_i − reference_i) / capacity_iRetain N or N·m alongside normalized results
Worst channelmax absolute e_iUsed by this worksheet project rule
Normalized RMSsqrt(sum(e_i²)/6)Summary only; does not replace per-axis acceptance

Source basis: BIPM/JCGM: GUM and measurement uncertainty publications

Combined-load calibration worksheet showing hypothetical six-axis residuals: maximum 0.1000% FS and RMS 0.0866% FS
Original browser capture of this worksheet, 2026-11-04, using “Try hypothetical example”. Reference [150, 80, 600] N and [15, 22, 8] N·m; indicated [150.5, 80.25, 601.5] N and [15.05, 22.05, 8.025] N·m; capacities [500, 500, 1500] N and [50, 50, 50] N·m; U=0.04% FS, T=0.25% FS. Maximum error 0.1000% FS and normalized RMS 0.0866% FS. This demonstrates software execution with hypothetical inputs; it is not a physical test, customer result or calibration certificate.

8. Uncertainty and an agreed project decision rule

The tool implements a documented guard rule, not a universal accuracy class.

The default project tolerance is T=0.25% FS. The hypothetical example enters a conservative expanded error uncertainty U=0.04% FS common to all channels. Its guarded limit is T−U=0.21% FS, so e_max=0.1% FS is within this rule at this point. In real work, U must include reference, indicated reading, repeatability, drift, fixture and relevant covariance; a rig certificate alone is not the complete budget.

Unknown U leaves the result undecided; zero U is rejected as invalid physical measurement evidence. A zero-load or single-axis reference is labeled as not being a compound-load check, and reference or indicated values beyond an individual capacity block acceptance. If U≥T, the worksheet declines acceptance even at zero error. For known smaller U, e_max+U≤T is within the guarded limit; e_max>T is outside the project tolerance; the interval between is guard-band overlap. ILAC G8 discusses choosing and documenting decision rules. This tool does not calculate global false-accept risk, certify an instrument or map ISO 376 classes to fixed six-axis % FS limits.

Apply an agreed project guard rule: three sequential checks123
  1. State project tolerance T in % FS.
  2. Supply a conservative expanded error uncertainty U.
  3. Check max absolute normalized error + U ≤ T.
Apply an agreed project guard rule. Unknown U or U ≥ T prevents acceptance in this worksheet.
8. Uncertainty and an agreed project decision rule — review checklist
Check or optionMethod / decisionEvidence or limitation
Missing readings or UCollect evidence; no acceptance statementZero must be entered explicitly, not assumed from a blank
max |e| + U ≤ T and U<TWithin this guarded project limitOnly this input point; no domain-wide claim
Guard-band overlap / outside TReview uncertainty or investigate deviationsDo not automatically upgrade the model or refit holdouts

Source basis: ILAC G8:09/2019 — Decision Rules and Statements of Conformity · BIPM/JCGM: GUM and measurement uncertainty publications · ISO 376:2011 — Force-proving instruments for uniaxial testing machines

9. Manufacturer combined-load limits

Individual channel limits are necessary checks and are insufficient to approve simultaneous loading.

Obtain the applicable manufacturer interaction surface or load-combination equations for the exact sensor, adapter and mounting arrangement. Do not assume a hypersphere, ellipsoid, sum-of-squares rule, generic 85% margin or simultaneous full scale on every channel. Different structural layouts have different interactions, with sign and moment-origin dependence.

The worksheet blocks a reference that exceeds any entered single-axis capacity. A vector below each capacity is still marked as having an unknown combined envelope. It cannot estimate stress, fatigue life or safe overload from these inputs. If evidence is unavailable, send the vector and fixture drawing for engineering review before applying it.

Check loading evidence separately: three sequential checks123
  1. Reject any reference component above its individual span.
  2. Get the exact manufacturer interaction diagram.
  3. Approve the sensor, fixture and vector combination before loading.
Check loading evidence separately. Below each channel span does not establish combined-load safety.
9. Manufacturer combined-load limits — review checklist
Check or optionMethod / decisionEvidence or limitation
One reference component over spanStop and revise before loadingNo positive point verdict allowed
Every reference component in spanCheck interaction rule separatelyDoes not prove combined structural safety
Moment origin changedTransform wrench and recheck limitsAn offset force generates additional moment

Source basis: Acta IMEKO (2017): Multi-component measuring device — uncertainty budget and signal cross-talk for combined loads · Carlson (2019): On the Calibration of Force/Torque Sensors in Robotics

10. Stability, dwell and zero-return records

Separate changing zero from load-dependent response.

Record temperature near the sensor and reference chain, power-on time, fixture equilibrium and the settling criterion used for each reading. Determine dwell from observed creep and stability rather than assuming that every assembly needs a cleanroom or a 24-hour soak. Preserve the pre-tare raw output so drift remains observable.

Interleave repeated reference points and unloaded returns. If zero changes systematically with run order, randomize feasible test blocks and investigate thermal or mounting effects before interpreting a residual surface. The worksheet zero-check allowance is a scheduling convention and does not prescribe a metrological sampling interval.

Separate drift from loading effects: three sequential checks123
  1. Log temperature, warm-up and initial raw zero.
  2. Repeat reference vectors with intermediate zero returns.
  3. Investigate time-dependent changes before refitting.
Separate drift from loading effects. Dwell and stabilization depend on measured behavior and the agreed procedure.
10. Stability, dwell and zero-return records — review checklist
Check or optionMethod / decisionEvidence or limitation
Before loadingLog warm-up and unloaded stabilityDemonstrate equilibrium using measurements
During the sequenceRepeat selected vectors and zero returnsTrack time, temperature and loading history
After unloadCompare to initial raw zeroInvestigate unexplained shifts before refitting

Source basis: BIPM/JCGM: GUM and measurement uncertainty publications

11. Fixture geometry, signs and reference origin

An origin error can look like cross-talk even with a correct calibration matrix.

Record mounting faces, bolt procedure, adapter stack, sensor axes and the location where reference forces act. For a wrench moved from origin O to O_prime with r pointing from O_prime to O, use M_Oprime = M_O + r × F in the same orientation. Apply a consistent rotation to force and moment if axes also change.

For a hypothetical 100 N force along +Z acting 0.1 m along +X from the chosen origin, r × F gives My=−10 N·m by the right-hand convention. Verify such a known-vector check in the host pipeline. Fixture compliance, tilt, friction and uncertain moment arms belong in the reference model and uncertainty budget; no universal flatness or stiffness ratio is specified here.

Keep wrench origin and signs consistent: three sequential checks123
  1. Record mounting geometry and reference load location.
  2. Transform force and moment into one sensor frame.
  3. Verify with a known offset force using M = r × F.
Keep wrench origin and signs consistent. Origin offsets can look like cross-talk even when the matrix is correct.
11. Fixture geometry, signs and reference origin — review checklist
Check or optionMethod / decisionEvidence or limitation
Origin and orientationDocument r and the direction of each axisRetain a drawing with the test record
Known offset forceCheck sign and moment using r × FDistinguishes transform errors from sensor residuals
Fixture deformationMeasure or bound geometry under loadInclude in reference uncertainty where relevant

Source basis: Carlson (2019): On the Calibration of Force/Torque Sensors in Robotics · BIPM/JCGM: GUM and measurement uncertainty publications

12. Static results and dynamic application boundaries

A static combined-load check does not validate a robot contact loop at operating bandwidth.

When a payload accelerates, the measured wrench includes inertial contributions. The assembled sensor, adapter, tool and controller also introduce frequency-dependent gain and phase. Validate them at the relevant frequencies and amplitudes; a static residual table does not establish those properties.

There is no universal usable-bandwidth rule at 30% of resonance, and a filter does not replace dynamic characterization. If only static evidence is available, constrain the stated result to the static conditions and request dynamic system testing for impact, vibration or rapid force control.

Keep static and dynamic evidence distinct: three sequential checks123
  1. Establish settled-load residuals.
  2. Characterize the assembled system magnitude and phase.
  3. Validate the intended motion, filters and control bandwidth.
Keep static and dynamic evidence distinct. Static calibration alone does not establish dynamic accuracy.
12. Static results and dynamic application boundaries — review checklist
Check or optionMethod / decisionEvidence or limitation
Slow held loadUse the agreed settled-reading protocolStatic worksheet scope
Motion with payloadAccount for gravity and inertiaRequires application-specific modeling and validation
Impact or periodic excitationMeasure magnitude and phase responseNo dynamic claim inferred from static torque practice

Source basis: ASTM E2428-15a — Calibration and Verification of Torque Transducers (historical edition) · Carlson (2019): On the Calibration of Force/Torque Sensors in Robotics

13. Drift, collisions and investigation triggers

Choose investigation limits from your baseline and operational risk.

Maintain trend records for zero returns, check-load response and repeated compound vectors. Compare them with the project tolerance and their uncertainty. A change can originate in the sensor, mount, cable, electronics or import pipeline. Preserve as-found records before changing tare, firmware or coefficients.

After an overload, collision, fixture replacement or unexplained trend change, follow the manufacturer procedure and assess whether the previous calibration remains applicable. This page does not invent a universal 150% overload trigger or mandatory recalibration interval. Use the linked interval guide for that separate task.

Investigate changes against a baseline: three sequential checks123
  1. Retain as-found zero and known-vector results.
  2. Check mounting, electronics and coefficient versions.
  3. Follow manufacturer assessment after collisions or overload.
Investigate changes against a baseline. No universal overload percentage or recalibration interval is inferred here.
13. Drift, collisions and investigation triggers — review checklist
Check or optionMethod / decisionEvidence or limitation
Unexpected zero shiftRetain as-found record and investigate chainDo not hide drift by repeated tare
Mount / firmware changeRepeat known-vector and compound checksCheck whether calibration conditions changed
Collision or overloadFollow manufacturer assessment procedurePrior acceptance cannot establish continued validity

Source basis: ISO/IEC 17025:2017 — Competence of testing and calibration laboratories · BIPM/JCGM: GUM and measurement uncertainty publications

14. Handoff, cost and evidence gaps

Deliver a reproducible calibration package rather than an unexplained matrix.

Ask for a versioned coefficient file with dimensions, units, normalization, bridge order, force/moment order, origin, tare convention and firmware identity. Import known vectors into the host and compare with the laboratory outputs. A machine-readable certificate can assist data handling but does not itself prove signature authenticity, controller compatibility or measurement accuracy.

Agree quotation scope before testing: fixture design, repeated sign series, independent confirmation, full uncertainty evaluation, coefficient import support and retesting can dominate a simple run-time allowance. If combined-load capability or evidence is missing, narrow the declared domain, use a qualified laboratory, or gather additional verification data. No product approval, measured case result or laboratory price is inferred on this page.

Make the handoff reproducible: three sequential checks123
  1. Version units, axes, feature order and coefficients.
  2. Import and replay independent known vectors.
  3. Archive raw records, uncertainty and decision rule.
Make the handoff reproducible. Machine-readable data still require validation in the host system.
14. Handoff, cost and evidence gaps — review checklist
Check or optionMethod / decisionEvidence or limitation
Minimum handoffRaw records + coefficients + conventions + holdout errorsInclude uncertainty and the agreed decision rule
Cost / complexity riskQuote fixture, repeats, setup and rework separatelyBudget hours are not a binding service price
Missing combined evidenceRestrict claims and request qualified testingDo not claim full-domain calibration from one point

Source basis: PTB Digital Calibration Certificate project · ISO/IEC 17025:2017 — Competence of testing and calibration laboratories · ILAC G8:09/2019 — Decision Rules and Statements of Conformity

Six Worked Scenarios: Hypothetical Examples and Test Protocols

The first two examples use fully stated hypothetical values. The remaining scenarios are proposed protocols with unknown outcomes. None is a measured product case study.

Hypothetical worked example

Cobot sanding: calculate the supplied point

Application & Transducer: Static mixed shear, normal force and moments (Generic capacities; no identified product)

Simultaneous Operational Wrench: [150,80,600] N; [15,22,8] N·m

Mechanical Challenge:

Separate individual residuals from a normalized average.

Calibration Methodology:

Use indicated [150.5,80.25,601.5] N and [15.05,22.05,8.025] N·m; capacities [500,500,1500] N and [50,50,50] N·m.

Single-Axis ResidualNot supplied
Combined Residualmax 0.1% FS
Matrix ConditioningUnknown
Cross-Talk ReductionNot measured
Engineering Takeaway: With illustrative U=0.04% FS and T=0.25% FS, this point meets e_max+U≤T. Load safety and full-domain accuracy remain unverified.
Hypothetical worked example

Wind tunnel: a close tolerance needs uncertainty

Application & Transducer: Static balance verification (Generic capacities; no identified product)

Simultaneous Operational Wrench: [150,80,600] N; [15,22,8] N·m

Mechanical Challenge:

A nominally small error can overlap a guarded limit.

Calibration Methodology:

The wind tunnel preset changes indicated Fx to 150.4 N at 500 N capacity: eFx=0.08% FS. Other errors are 0.05% FS.

Single-Axis ResidualNot supplied
Combined Residualmax 0.08% FS
Matrix ConditioningUnknown
Cross-Talk ReductionNot measured
Engineering Takeaway: At T=0.1% FS and U=0.04% FS, the 0.06% guarded limit is exceeded. This is guard-band overlap, not demonstrated acceptance.
Illustrative protocol; no test data

Humanoid ankle: preserve static scope

Application & Transducer: Ground-contact assembly (Configuration and ratings unknown)

Simultaneous Operational Wrench: To be specified from the application

Mechanical Challenge:

Impact and inertial wrench differ from a settled static check.

Calibration Methodology:

Define approved static holdouts first; specify separate dynamic magnitude and phase validation with the assembled foot.

Single-Axis ResidualUnknown
Combined ResidualUnknown
Matrix ConditioningUnknown
Cross-Talk ReductionUnknown
Engineering Takeaway: A static worksheet cannot qualify impact response or balance-loop performance.
Illustrative protocol; no test data

Low-force teleoperation: retain absolute units

Application & Transducer: Low-force research instrument (No medical approval or product rating asserted)

Simultaneous Operational Wrench: Small application forces; reference chain to be defined

Mechanical Challenge:

An acceptable % FS result may still be too large in newtons.

Calibration Methodology:

Specify absolute force error and noise requirements, then validate against a suitable low-range reference under compound moments.

Single-Axis ResidualUnknown
Combined ResidualUnknown
Matrix ConditioningUnknown
Cross-Talk ReductionUnknown
Engineering Takeaway: Add a physical-unit error budget; this page provides no clinical suitability evidence.
Illustrative protocol; no test data

Fastening: separate torque from offset forces

Application & Transducer: Torque and axial loading assembly (Configuration and ratings unknown)

Simultaneous Operational Wrench: Application-defined Fz and Mz with side loads

Mechanical Challenge:

Tool offsets introduce bending moments alongside rundown torque.

Calibration Methodology:

Document origin and adapter geometry; verify combined axial force, torsion and representative side-load signs.

Single-Axis ResidualUnknown
Combined ResidualUnknown
Matrix ConditioningUnknown
Cross-Talk ReductionUnknown
Engineering Takeaway: Obtain the approved interaction diagram and reference uncertainties for the actual fixture.
Illustrative protocol; no test data

Polishing head: isolate thermal and loading effects

Application & Transducer: Multi-axis polishing research (Configuration and ratings unknown)

Simultaneous Operational Wrench: Application-defined normal load and tangential moments

Mechanical Challenge:

Temperature and time drift can be confused with compound sensitivity.

Calibration Methodology:

Interleave zero returns and repeated reference vectors while logging temperature and dwell; retain as-found records.

Single-Axis ResidualUnknown
Combined ResidualUnknown
Matrix ConditioningUnknown
Cross-Talk ReductionUnknown
Engineering Takeaway: No surface-thickness, process-yield or cross-talk improvement is predicted without test data.

28 Decision FAQs on 6-Axis Combined Calibration

Practical answers to common engineering questions across rig kinematics, matrix conditioning, DoE algorithms, and site commissioning.

Rig Mechanics (7 Questions)

Does a Stewart platform have a fixed uncertainty?

No. Obtain the facility uncertainty for the actual vector, range, fixture and reference chain. The rig selector does not insert an uncertainty value.

Can deadweights create every independent wrench?

A force applied at an offset generates coupled moments. Geometry and available load directions constrain the attainable wrench combinations.

Is staying below all six capacities safe?

It is only an individual-span check. The manufacturer combined-load interaction rule and mounting limits are still required.

Which moment origin should I use?

Use the same documented origin for reference and indicated outputs. Transform offset forces and moments before comparing them.

Must every sensor soak for 24 hours?

No universal duration is stated here. Use the agreed procedure and observed thermal and zero stability.

How should friction enter the analysis?

Characterize or bound relevant pulley, joint and fixture friction and include it in the reference model and uncertainty budget.

What drawing should accompany an inquiry?

Send sensor axes, moment origin, load application points, adapter geometry and the requested signed vector domain.

Mathematics & Conditioning (7 Questions)

Can single-axis calibration identify cross-sensitivity?

Yes, for a linear model, if all outputs are recorded for the independent reference axes. Compound verification tests whether the linear relationship remains adequate.

What does 6×27 mean?

Each of six outputs uses six linear features, six squares and 15 unique pair products after tare removal. A fitted intercept adds a 28th feature.

Does quadratic always outperform linear?

No. It can fit training data more closely yet generalize poorly. Compare frozen independent measurements and their uncertainties.

Why is the condition number unavailable?

No calibration matrix or design matrix is supplied. Channel capacities and rig type cannot determine its singular values.

What does FS mean here?

The positive channel capacity: for a ±500 N channel, FS=500 N. It is not the 1000 N peak-to-peak span.

Is the result RSS or RMS?

The summary is normalized RMS, sqrt(sum(e_i²)/6), with e_i in % FS. It is not a physical force/moment vector radius.

Why do I see signed errors?

Error is indicated minus reference. Keeping signs helps reveal bias, reversed polarity and correlated behavior across axes.

DoE & Verification (7 Questions)

Is the worksheet a calibration matrix solver?

No. It computes residuals from already indicated outputs and provides an editable point-count budget. Fit and assess the actual matrix externally.

Does a holdout percentage guarantee independence?

No. Independence depends on excluding the final points from fitting and model selection, not on their proportion.

Are the example vectors approved loading instructions?

No. They are hypothetical. Check the actual sensor and fixture interaction limits before applying any load.

Why does one point not certify the domain?

It tests only one vector and its recorded conditions. Sign combinations, magnitudes, repeats and time effects require additional evidence.

What happens when a reading is blank?

Its error remains unknown. All six indicated outputs are required for a complete maximum/RMS summary and guarded decision.

Does the planner create a D-optimal design?

No. It budgets runs. A separate design must identify all model terms, satisfy loading constraints and pass rank and conditioning checks.

How is run time estimated?

Total planned runs times editable minutes per point divided by 60. Setup, stabilization, repeated series and rework are excluded.

Industrial Deployment (7 Questions)

Is 0.25% FS an ISO Class 0.5 rating?

No. It is an editable project target. ISO 376 covers force-proving instruments for uniaxial testing machines and cannot be mapped to this generic six-axis label.

Why is expanded uncertainty required?

The selected rule compares maximum error plus U with the project tolerance. U must conservatively bound all six channel error uncertainties at the stated coverage.

What if U equals or exceeds the tolerance?

The worksheet gives no acceptance because there is no positive guarded acceptance interval. Review the uncertainty chain or the project requirement.

Does a within-limit result prove safe loading?

No. Measurement error and structural load capability are separate evidence questions. The combined envelope remains unknown here.

Does ASTM E2428 prescribe the six-axis method?

No. The cited historical edition addresses static torque transducers. EURAMET cg-18 addresses weighing instruments; neither is presented as a six-axis combined-load mandate.

What should be checked during coefficient import?

Confirm units, feature order, row and column order, scaling, origin, tare, version and known-vector outputs. Machine-readable delivery alone is insufficient.

What is the minimum next step without measurements?

Use the budget and record template to request an agreed test plan, approved interaction limits and an uncertainty statement from the laboratory.

Primary Metrological References & Consensus Standards

References checked on 2026-11-04. Research findings, standards scopes and our project recommendations are distinguished below. Public summaries do not establish compliance with a full standard or any product approval.

Combined-load calibration interfaces directly with coordinate frame alignment and electrical telemetry. To verify right-hand polarities and spatial transformations, see 6-axis force sensor sign convention verification, review calibration certificates with calibration certificate interpretation checklist, or inspect calibration intervals with the calibration interval decision tool.

Need Custom Combined-Load Calibration or Multi-Axis Rig Review?

Send your signed operational wrench vectors, reference origin, mounting drawing, required physical-unit and % FS limits, and available test records. Request review of the loading plan, uncertainty evidence and coefficient conventions; capabilities and service scope require confirmation.

Related engineering resources: 6-axis load cell design & calibration overview, calibration laboratory qualification guide, or all engineering resources.

Discuss Calibration Requirements ↗